COMPARE GREENDUCT™ PRODUCTS TO OTHER FLEXIBLE DUCT

GREENDUCT™ RT 1.65 ULTIMATE
 (Suitable for tropical & alpine applications)

Mechanically locked “Unilok” duct core = R 0.0
Polyester insulation blanket 90mm thick = R 1.5*
Green P.E.T outer duct jacket = R 0.15

RT (Overall Thermal Value ) = RT 1.65

175%* MORE
THERMAL EFFICIENT THAN WESTAFLEX
RT 0.6 STANDARD.
RT EXCEEDS AUSTRALIAN BUILDING CODE (BCA 2009)

GREENDUCT™ RT 1.15 SUPERIOR

Mechanically locked “Unilok” duct core = R 0.0
Polyester insulation blanket 60mm thick = R 1.0*
Green P.E.T outer duct jacket = R 0.15

RT (Overall Thermal Value ) = RT 1.15

83%* MORE
THERMAL EFFICIENT
THAN WESTAFLEX
RT 0.6 STANDARD.
RT EXCEEDS AUSTRALIAN
BUILDING CODE (BCA 2009)

GREENDUCT™ RT 75 PREMIUM

Mechanically locked “Unilok” duct core = R 0.0
Polyester insulation blanket 40mm thick = R 0.6*
Green P.E.T outer duct jacket = R 0.15

RT (Overall Thermal Value ) = RT 0.75

20%* MORE
THERMAL EFFICIENT THAN WESTAFLEX
RT 0.6 STANDARD.
RT EXCEEDS AUSTRALIAN BUILDING CODE (BCA 2009)

WESTFLEX RT 0.6 STANDARD

Glue duct core = R 0.0
Polyester insulation blanket 40mm thick = R 0.45*
Silver P.E.T outer duct jacket = R 0.15

RT (Overall Thermal Value ) = RT 0.6

RT MEETS 
AUSTRALIAN
BUILDING CODE (BCA 2009) THERMAL REQUIREMENTS

EXAMPLE OF GLUED DUCT ON THE MARKET

Glue duct core = R 0.0
Polyester insulation blanket 17mm thick = R 0.33*
Silver P.E.T outer duct jacket = R 0.15

RT (Overall Thermal Value ) = RT 0.48

RT  DOES NOT MEET  AUSTRALIAN BUILDING CODE (BCA 2009)
THERMAL REQUIREMENTS

ASK YOUR CONTRACTOR TO SHOW YOU A SAMPLE OF THE DUCT THEY ARE PROPOSING TO PUT IN YOUR HOME.
*Data provided by Autex Pty Ltd **“Westaflex RT 0.6 standard” refers to “Tradeflex RT 0.6”.

COOLING SYSTEMS AND HEAT GAIN IN DUCT

POORLY INSULATED DUCT = HIGHER RUNNING COSTS
On a hot 40° day the temperature in a roof space can get to 55°-70°C. Most ducted A/C units are installed into roof spaces and blow cold air into flexible duct between 14-16°C. It is the job of the insulation surrounding the duct to keep the air inside it as cold as possible thus avoiding temperature increase (heat gain) as the air travels through the duct to all vents in your system.

GREENDUCT ™ = **LOWER RUNNING COSTS.

HEATING SYSTEMS AND HEAT LOSS IN DUCT

POORLY INSULATED DUCT = HIGHER RUNNING COSTS
On a cold 0-5°C day or night the temperature in a roof space or under a floor is about the same as outside 0-5°C. Most ducted heating units blow hot air into the flexible duct at around 60°C. It is the job of the insulation surrounding the duct to keep the air inside it as hot as possible thus avoiding temperature decrease (heat loss) as the air travels through the duct to all vents in your system.
GREENDUCT ™ = **LOWER RUNNING COSTS.

GREENDUCT ™ PRODUCTS
Made in Australia, Exceeds BCA 2011 (Building Codes of Australia) Thermal Tests, Complies to AS4589.1 Thermal Tests, Complies to AS4254 Fire and Mechanical Tests, Test Reports - BCA 2011 Requirements and BCA 2011 zone maps are available, Available in Acoustic.